Mercury Security Corporation, Copyright 2011 EP2500 DOC 10107-0030 REV: 1.03 Page 2
Information subject to change without notice.
Jumpers:
The EP2500 processor hardware interface is configured using jumpers to setup the port interface and
end of line termination.
NOTE 1: Observe polarity connection to LED. External current limiting is not required.
NOTE 2: Jumpers J7, J8, J9, and J10 to do not effect the operation of the Lantronix unit.
DIP Switches:
The four switches on S1 DIP switch configure the operating mode of the EP2500 processor. DIP
switches are read on power-up except where noted. Pressing switch S2 causes the EP2500 to reset.
All other switch settings are unassigned and are reserved for future use.
Factory Default Communication Parameters:
Network: static IP address = 192.168.0.251
Communication address: 0
Primary Host port: IP server, no encryption, port 3001.
Alternate Host port: RS-232, 38400 baud, no encryption, no flow control.
1 2 3 4 Definitions
OFF OFF X OFF Normal operating mode
ON X X X
After initialization, enable default User Name (admin) and Password
(password). The switch is read on the fly, no need to re-boot.
OFF ON X OFF Use factory default communication parameters.
ON ON X OFF
Use OEM default communication parameters. Contact system
manufacture for details. See Bulk Erase below.
X X ON X Disable TLS secure link. Switch is read only when logging on.
JUMPERS SET AT DESCRIPTION
J2 N/A Factory use only
J3 N/A Factory use only
J4 OFF Port 2 RS-485 EOL Terminator is off
ON Port 2 RS-485 EOL Terminator is on
J5 OFF Port 3 RS-485 EOL Terminator is off
ON Port 3 RS-485 EOL Terminator is on
J6 N/A Lantronix Micro100 connection - Port 1
J7, J8, J9 232 Port 1 is RS-232
485 Port 1 is RS-485
J10 OFF Port 1 RS-485 EOL Terminator is off
ON Port 1 RS-485 EOL Terminator is on
J11 N/A Factory use only
J12 N/A Factory use only
J13 N/A Factory use only
J14 N/A Remote status LED # 1, see note 1
J15 N/A Remote status LED # 2, see note 1
J16 N/A Remote status LED # 3, see note 1
J17 N/A Remote status LED # 4, see note 1